Quick Answer
You can safely move Bluebot to a new pipe or location, clean or replace the ultrasonic pads if needed, and then reinstall the device. Proper pad care and re-adding the device in the app ensures accurate readings after a move.
Moving Bluebot to a New Location
Remove Bluebot from the Pipe
Unplug the Bluebot from power
Use both hands to open the clamps
Gently rock the device side to side to break the suction from the ultrasonic pads
Remove the device from the pipe
If the pads look dirty:
Lightly wipe them with a damp cloth
If pads are heavily soiled, they should be replaced
Remove Bluebot from the App (Before Reinstalling)
Before reinstalling Bluebot on a new pipe, remove it from the app.
Open the Bluebot app
Go to the device list
Swipe left on the device name
Confirm removal
This removes the device from the active group but does not delete your data.
You can now set the device up again following the normal setup flow.
Cleaning vs. Replacing Ultrasonic Pads
When Cleaning Is Enough
Bluebot comes with ultrasonic pads pre-installed. If:
Pads are clear
You can see through them
There is only light grime or cloudiness
You can clean them:
Use warm water and mild soap
Gently wipe with a soft cloth
Let them air dry before reinstalling
Bluebot is waterproof, so cleaning the pads will not damage the device.
When Pads Should Be Replaced
Replace the pads if:
They are heavily soiled
They no longer stick well
They are damaged or opaque
Any dirt, paint, or debris on the pads or pipe can weaken the ultrasonic signal and affect accuracy.
How to Replace Ultrasonic Pads
Use the silver C-holders to prop the Bluebot clamps open
Slide one C-holder onto each open arm
Carefully peel off the old pads (start from the edges and take your time)
Install New Pads
Each white circular sensor needs one new pad
Remove the protective backing from the pad
Place the pad directly over the clear sensor window
The stickier side should face the sensor when possible
The less sticky side should face the pipe
This helps keep the pads attached to the device during future removal.
Finishing Up
Carefully remove the C-holders from each arm
Ensure the clamps close smoothly
Bluebot is now ready to rescan or reinstall on the pipe
After Reinstallation
Once Bluebot is reinstalled:
Follow the app prompts to complete setup
Allow the device to rescan the pipe
Confirm normal readings in the app